How-to

How to size a dehumidifier for a UK flat or older house

What 10L, 20L and 25L labels really mean, why they are measured at 30°C, and how to pick a dehumidifier size from your own humidity readings and room.

By Checked and updated

On this page (7 sections)

Measure the room’s humidity and temperature first, choose compressor or desiccant by temperature, and treat the litres-per-day number as a way to compare models, not a promise. Most headline figures are measured at 30°C and 80% humidity, far warmer and wetter than a British bedroom in winter, so at 20°C and 60% humidity, closer to a heated room, expect a machine to remove less than half its label. Then match the tank and drainage to how often you can empty it.

External sources were checked on 16 November 2026. We have not tested any machine. Figures below are manufacturers’ published specifications, with their test conditions.

What “20 litres a day” means

A dehumidifier’s name or headline usually gives its extraction rate: the water it can remove in 24 hours. That figure is measured under a stated temperature and humidity, and the conditions make a large difference.

Meaco publishes several conditions for each Arete model, which shows the effect clearly. All figures below are from Meaco’s official UK product pages, checked on 16 November 2026:

Model 30°C / 80% RH (headline) 27°C / 60% RH 20°C / 60% RH 20°C as a share of headline
AdArete One 6L 6 L/day 3.5 L/day 2.63 L/day about 44%
AdArete Two 10L 10 L/day 6 L/day 4.19 L/day about 42%
AdArete Two 20L 20 L/day 12 L/day 8.50 L/day about 43%
AdArete Two 25L 25 L/day 15 L/day 10.85 L/day about 43%

So at 20°C and 60% humidity, closer to a heated UK room, Meaco’s own figures show these machines removing a little over 40% of the number in their name. A cooler room or drier air would mean less again. Other manufacturers often give only the 30°C/80% figure: Pro Breeze’s 12L manual, for example, gives “12L per day at 30°C and 80% relative humidity”. None of the Meaco or Pro Breeze documents we read names a test standard.

When you compare two machines, compare them at the same condition. A 12L figure at 30°C/80% RH and a 10L figure at 27°C/60% RH are not comparable.

Desiccant machines are often rated differently. Meaco’s AdDD8L page gives 3.5 L/day on fan speed 1 and 7.5 L/day on fan speed 2 at 20°C/60% RH, and its manual gives an 8 L/day nameplate figure. A desiccant’s output also falls less in a cold room than a compressor’s, which is why “8L” and “10L” across the two types do not line up. See compressor vs desiccant.

The tank is a different number

The litres in the name are not the tank. The Arete One 6L has a 1.8 L tank, the Arete Two 10L 2.5 L, and the Arete Two 20L and 25L 4.8 L. The DD8L’s is 2 L. A machine extracting 8 litres in a day with a 2.5 L tank needs emptying three times, or a drain hose. Most machines stop when the tank is full.

Start from your readings, not the floor area

A hygrometer reading over a week tells you more about the size you need than the square metres. A dry, well-ventilated room that peaks at 65% after a shower needs much less than a north-facing bedroom that sits at 75% all night with washing on the airer. See best hygrometers for how to take the readings, and keep a note of the room’s temperature.

There is no official UK formula for sizing a domestic dehumidifier that we could find. Manufacturers publish rules of thumb. Meaco’s Adhelp centre, checked on 16 November 2026, suggests:

It suggests choosing a size up if you dry laundry indoors, see mould or condensation daily, have solid walls or poor ventilation, or want quieter running on a lower fan speed. Meaco does not say how these bands were worked out, and they are a seller’s guidance. Its individual product claims do not always agree with each other either: the Arete Two 20L page says it is designed for 3-5 bed houses, while the Arete Two 20L/25L manual says the machines “can be used to dry up to a 3-bedroom house”. We report both.

CSE’s advice is simpler: buy a dehumidifier that removes at least 5 litres every 24 hours (CSE, condensation, damp and mould). CSE does not say at what test condition, so read that as a floor, not a target.

Three common homes

These are qualitative examples to help you think, not a sizing chart.

A heated one-bedroom flat with washing on an airer. The moisture comes from people, cooking, showers and laundry. A compressor in the 10-12L class (by its 30°C headline) is the usual starting point, moved to whichever room has the washing. If washing dries indoors most days, the size-up advice above applies, and a bigger tank saves emptying. Compare models in our buying guide and our laundry guide.

One damp bedroom in a larger house. If the rest of the house is fine, you are sizing for a room, not a house. A small machine such as the Arete One 6L, which Meaco describes as ideal for rooms up to 25 m², may be enough, and is easier to live with at night. See quiet dehumidifiers for bedrooms.

A cold cellar, garage-side room or unheated older house. Temperature matters more than size. A compressor sized for the house on paper may collect very little in a room at 8°C. A desiccant such as the DD8L keeps working in the cold, with higher electricity use. And if water is coming through a wall, no size of dehumidifier fixes that: find the source first. See Meaco Arete vs DD8L.

Continuous drainage or tank emptying

If the machine will run for long periods, or extract more in a day than its tank holds, a drain hose saves you emptying it. It needs a drain, sink or outside gully below the machine’s outlet, because the water runs out by gravity.

Every Meaco model in this guide lists continuous drainage with the hose not included. The Arete Two manual says it fits a standard garden hose with a 12.5 mm internal diameter; the DD8L manual says to use a hose with an 8 mm internal diameter. Check your own model’s manual before buying a hose.

If there is nowhere to drain to, plan around the tank. A 4.8 L tank emptied once in the evening suits most routines better than a 1.8 L tank that fills during a laundry day.

Common mistakes

Buying a tiny “mini” unit for a wet flat. Very small units are sold with tanks and extraction rates measured in millilitres rather than litres. Read the extraction figure and its conditions before assuming it will cope with laundry or a damp bedroom.

Buying the biggest machine for a small bedroom. A 25L machine in a box room is heavier, usually louder on high, and costs more per hour than it needs to. Meaco’s manual figures for the Arete Two 25L are 40/42/50 dB on low, medium and high, against 35/38/44 dB for the 10L. A bigger machine on a low fan can be quieter than a small one flat out, but only if the job suits it.

Reading the label as a promise. A “20L” machine will not take 20 litres out of a 19°C flat in January. Use the label to compare, and look for a figure at 20°C or similar where the maker gives one.

Sizing for the house when the problem is one room. Measure each room. A dehumidifier works best in a room with the door closed, as CSE notes; one machine on a landing will not reach a closed bedroom.

Ignoring running costs. A bigger machine draws more power. The Arete Two 25L lists 250 W at 20°C/60% RH against 136 W for the 10L. Our running-cost guide shows how to work out the difference at your unit rate.

Now choose a machine

Once you know the room, the temperature and roughly how much moisture you are dealing with, go to the buying guide for current models.

Sources checked on 16 November 2026