Dehumidifier not collecting water: what to check before you call the repair line
Why a dehumidifier runs but fills no tank in a UK winter: cold rooms, dry air, settings, tank, hose and filter, checked against the makers' manuals.
Checked and updated
On this page (11 sections)
A dehumidifier that runs but leaves the tank nearly empty is usually not broken. The commonest reasons are that the room is too cold for a compressor machine to pull much water out, that the air has already reached the humidity you set so the machine has stopped, or that it is new and still working down a large space. The makers’ own manuals list all three as normal.
Check in this order: room temperature and humidity, settings, tank and float, drain hose, then filter and airflow. Only then call the maker. Everything below comes from the manufacturers’ manuals and help pages; Drynook has not tested these machines.
Is it the room, not the machine?
Temperature
A compressor dehumidifier works by cooling air over cold coils, so it collects far less in a cold room. Meaco’s Adhelp centre says compressor machines “perform best in warmer conditions, typically above 10°C, with optimal performance around 16°C+.”
On the AdArete Two 20L product page, Meaco lists 8.50 litres a day at 20°C and 60% humidity, but only 3.35 litres at 10°C and 60%. Same machine, same humidity, under half the water. A north-facing box room with the radiator off can sit nearer 10°C than 20°C in January.
Below 5°C, these compressor machines stop altogether. The Arete Two manual gives its operating range as 5°C to 35°C, and the Devola DV12L manual says “When the ambient temp is lower 5 °C or higher than 35°C, the dehumidifier will stop operation.”
De’Longhi’s UK help page adds that a cold room can show “a higher humidity level but without moisture to collect.”
Defrosting is normal
In a cool room the coils can frost over, so compressor machines stop now and then to defrost. Ebac’s FAQs put it simply: “A dehumidifier in defrost mode is not removing moisture”. What you see depends on the model:
- Devola DV12L. Between 5°C and 18°C it defrosts automatically. The manual says “The compressor will stop working and the fan will continue running during defrosting” and “The display will not change during this process.” It also says “You may hear gurgling or flowing sounds from the refrigerant during this process - this is completely normal.”
- Meaco Arete Two. The dehumidifying indicator goes out. The manual says it “will turn off when the dehumidifier is checking the humidity level and when the dehumidifier is defrosting - this is normal.”
So a fan that keeps running while the tank stays empty is not, on its own, a sign of a fault.
Humidity already at the target
Once the room reaches the level you set, the compressor stops. The Devola manual says that in Auto mode, “If humidity drops below the set level, the compressor and the fan switches off.” The Arete Two then checks again: “Every 30 minutes the fan will run and check the humidity level”. Its troubleshooting table adds: “below 45%RH the dehumidifier will not collect much water as there isn’t enough moisture in the environment.”
Check with a separate hygrometer
Put a separate digital hygrometer in the room for a day or two, away from the window and radiator. Pro Breeze’s help page on readings says “It’s normal for there to be a 5% difference in humidity levels between dehumidifiers”, so do not expect the two to match exactly.
How to read it:
- Below about 45%, or at or below your set level: an empty tank is what you would expect.
- Well above your set level, but the room is cold: a compressor will collect little. See the last section.
- Well above your set level in a heated room, and still nothing after a few hours: work through the checks below.
Our hygrometer guide explains what to buy and where to put it. Its pick, based on the maker’s published accuracy rather than a test, is the SwitchBot Meter Plus.
Check the settings
Target set too high. If the target is above the room’s humidity, the machine waits. De’Longhi’s UK page says to “Check that your set humidity level is lower than the current humidity level” and, on models without a digital display, “set the humidistat to the lowest setting.” On the Arete Two, Meaco’s fix is to “Use the Smart Humidity Mode button to reduce the target humidity level.”
Air purification mode. On machines that also purify, this mode collects nothing. The Arete Two manual says “In Air Purification Mode the dehumidifier will not dehumidify, it will simply purify the air.” Ebac’s FAQ makes it the first thing to check: “No water is collected in this mode.”
Timer or laundry mode. An off-timer stops the machine after the set hours. Laundry modes end on their own too: the Arete Two’s runs for 6 hours, then “the dehumidifier will turn off”, and the DD8L’s does the same.
Sleep mode. On the Devola, sleep mode stops the compressor below 57% humidity and restarts it above 63%. A room at 55% gets nothing.
Child lock. It does not stop collection, but explains dead buttons: on the Arete Two, “once locked you will not be able to change any settings or turn the dehumidifier off.”
Continuous mode is the test. The Arete Two’s Continuous setting will “continue to run and only turn off when the water tank is full, regardless of the humidity level.” A few hours of that in a warm room should produce some water.
Do not use a plug-in timer or smart plug instead. Devola says “Do not use with any external switching device”, and the Arete Two manual says one “will invalidate the warranty.”
The tank and the float
A tank not pushed fully home stops the machine and lights the tank-full light, even when empty. The Devola manual says to “Check that the tank is correctly inserted if the “Water Tank Full” indicator remains on.” The Meaco DD8L manual says the same: if the light “stays on and the unit does not start up then the tank is not correctly fitted.”
A float inside the tank tells the machine when it is full. The Arete Two manual says “It is essential that the float is NOT removed from the water tank”. For an FL error with an empty tank, Pro Breeze blames a stuck water sensor on the left of the tank and suggests gently moving it a few times.
If a drain hose is fitted
With a hose attached, the tank stays empty by design. If no water comes out of the hose either, suspect the hose: the water moves by gravity only.
- Devola: “The pipe must run downhill to allow gravity flow.” and “Make sure the pipe is not kinked, bent, or blocked at any point.”
- Meaco Arete Two: “Make sure the hose runs downwards with no kinks, bends or blockages to allow the water to drain out via gravity.”
- De’Longhi’s UK page on continuous discharge: the hose should be “positioned lower than the base of the unit”.
- Pro Breeze’s help page asks for the hose and dehumidifier to be “at least 15cm higher than the sink/bucket”.
A hose that loops up over the side of a bath before dropping in will not drain. The DD8L manual also says to cut off excess tube.
Filter and airflow
A clogged dust filter cuts the airflow and the water with it. The Devola troubleshooting table lists it first under “The dehumidifier is not extracting moisture”, followed by a blocked air inlet or outlet. How often the makers say to clean it:
- Meaco Arete Two: “a minimum of every two weeks (not doing so could invalidate the unit’s warranty)”.
- Devola DV12L: “at least every two weeks”.
- Meaco DD8L: “at least every two weeks”, with a vacuum cleaner, not water.
- Ebac: “We suggest you vacuum your filters monthly”.
Then check what is around it: a curtain over the inlet or a clothes horse against it starves the machine. The Devola needs “a minimum 50cm clearance around all sides”; the DD8L manual says “min 30cm” from curtains or other objects. The Arete Two can stand close to a wall, but Meaco still warns against blocking its air intakes.
A new machine
A new machine must stand upright before you switch it on. The Arete Two manual says: “Leave the dehumidifier to stand for six hours before turning it on.” The Devola DV12L manual gives two figures, “upright for 6 hours” on first use in one place and “upright for 24 hours” in its refrigerant safety notes, so with that machine wait the full day.
A new machine can also seem slow. The Arete Two manual says “Be patient, it takes a few weeks to initially dry a space when a dehumidifier is introduced for the first time.” In a heated flat that is already fairly dry, it may simply have little to find. Ebac’s FAQ notes that collection slows once the initial moisture has gone.
Signs it really is a fault
- Ice that keeps coming back. Pro Breeze’s advice for ice is to “Turn on fan mode and set to high speed. Leave it on the highest setting until the ice has completely melted away.” If it ices again in a heated room, contact the maker.
- Error codes. Trust only your own manual. On the Arete Two, E1, E2 and L2 mean “Please contact Meaco”; L3 is too warm, L4 too cold. On the Devola, E2 means the sensor “is damaged or affected with damp”; LO, HI, CL and CH are normal messages for very dry air, very humid air, below 5°C and above 35°C.
- No air coming out after the filter has been cleaned.
- The compressor never starts in a warm, humid room. Allow for the built-in pause first: the Devola has “a 3-minute delay between shut-off and restart.”
If you get here, unplug it and do not open it. These machines use R290, a flammable refrigerant, in a sealed system. The Arete Two manual says “it is part of a sealed system and must only be serviced by a trained Meaco engineer.” The Devola manual says “Do not attempt to open, repair or modify the appliance yourself. Contact the retailer.”
Contact the maker with the serial number and receipt to hand. On warranty, as the makers state it:
- Meaco: five years on the Arete, but AdMeaco’s warranty terms say “The Warranty must be activated by registering online” and “Meaco cannot provide Warranty service to products located outside mainland Great Britain”, unless Meaco shipped it there as part of the original sale. The original DD8L manual gives two years.
- Devola: the manual says “Register your product within 30 days of purchase to activate your warranty.” It does not state a length.
- Ebac: the FAQs say you must register within 30 days if you did not buy direct, and that the length “varies by model type”.
Wrong machine for the room
In a cold garage, unheated spare room or winter conservatory, a compressor will never collect much. Meaco’s Adguide to dehumidifier basics says that as the room heads towards freezing, compressor machines “with a defrost system are likely to only extract a tiny amount of water.” A desiccant is the usual answer; the DD8L manual says it works down to 1°C. See compressor versus desiccant, and how to size a dehumidifier if yours is simply too small.
Quick reference
| Symptom | Likely cause | What to do |
|---|---|---|
| Fan runs, tank empty, room cold | Too cold for a compressor, or defrosting | Heat the room or consider a desiccant |
| Stops and starts, little water | Humidity at or below target | Check with a hygrometer; lower the target |
| Nothing collected at all | Air purification mode, or target too high | Change mode; try Continuous for a few hours |
| Tank-full light on, tank empty | Tank not seated, or float stuck | Reseat the tank; check the float |
| Hose fitted, no water anywhere | Hose kinked or runs uphill | Make it run straight downhill |
| Weak airflow | Dirty filter or blocked inlet | Clean the filter; clear the space round it |
| New machine, little water | Settling in, or dry room | Stand upright first; give it time |
| Ice returns, error code, no air | Possible fault | Unplug, do not open, contact the maker |
Questions people ask
How much water should a dehumidifier collect in a day?
There is no fixed amount: it depends on the room’s temperature and humidity and on how much moisture the household makes. Meaco’s own table for the Arete Two 20L gives 8.50 litres a day at 20°C and 60% humidity and 3.35 litres at 10°C, against its 20 litre headline figure. Ebac’s FAQ says that “90% of homes can produce 3- 5 pints per day, but every home is different.”
Why is my dehumidifier blowing warm air?
That is normal. The Arete Two manual says “The dried air is passed over heating coils before it is blown into the room as part of the dehumidification process.” Desiccant machines blow out warmer air still, because they use a heater.
Why is my dehumidifier blowing cold air?
A compressor machine does not cool the room. Meaco’s manual says “the air may feel cooler because it is moving in the same way as the air from a fan in the summer feels cooler.” If it is blowing air but collecting nothing, check the room temperature and the target humidity first.
Is it normal for a dehumidifier to stop and start?
Yes. Once the room reaches the target, the compressor stops and the machine checks the air again later: every 30 minutes on the Meaco Arete Two and DD8L. Defrost cycles in cooler rooms also pause collection. On the Devola there is a 3-minute delay between shut-off and restart to protect the compressor.
Sources checked on 16 November 2026
- MeacoDry Arete Two 20L official page (water-removal table)
- MeacoDry Arete Two 20L/25L instruction manual, version EN303
- Meaco DD8L instruction manual, November 2019 edition
- Meaco help centre: dehumidifiers
- Meaco: a guide to dehumidifier basics
- Meaco warranty terms
- Devola DV12L instruction manual
- Ebac FAQs
- De’Longhi UK: my dehumidifier is not collecting water
- De’Longhi UK: continuous discharge but water still collects in the tank
- Pro Breeze help: continuous drainage not working
- Pro Breeze help: dehumidifier covered in ice
- Pro Breeze help: FL error
- Pro Breeze help: hygrometer shows a different humidity level